Liebert® FPC Power Distribution Cabinet
PREP TESTING - FAMILY Provides high quality, flexible power distribution for high-density data centers. It is engineered to combine the convenience and cost savings of a pre-packaged, factory-tested unit with the flexibility of a custom-tailored power system. This self-contained system provides power isolation, power distribution, computer-grade grounding and power monitoring.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Education
- Government
- Healthcare
- Retail and Wholesale
Liebert® FPC Power Distribution Cabinet
PREP TESTING - FAMILY Provides high quality, flexible power distribution for high-density data centers. It is engineered to combine the convenience and cost savings of a pre-packaged, factory-tested unit with the flexibility of a custom-tailored power system. This self-contained system provides power isolation, power distribution, computer-grade grounding and power monitoring.
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Education
- Government
- Healthcare
- Retail and Wholesale
Specifications
The rack-size Liebert® FPC power conditioning and distribution cabinet provides high quality, flexible power distribution for high-density data centers. It is engineered to combine the convenience and cost savings of a pre-packaged, factory-tested unit with the flexibility of a custom-tailored power system. This self-contained system provides power isolation, power distribution, computer-grade grounding and power monitoring. Liebert FPC ranges in capacity from 15kVA to 300kVA, 60Hz or 50Hz models. The system is available in 23.5" cabinet and 47” cabinet sizes and is designed to fit at the end of, or within, a row of racks, as well as in a standalone configuration.
|
Liebert FPC 15-125kVA
|
||||||
|---|---|---|---|---|---|---|
| 15-125kVA | 208, 380, 400, 415, 480, 600 VAC | 208/120, 380/220, 400/230, 415//240 VAC | 78.5 in | 23.5 in | 39.5 in | 750-1842 lbs |
| See more product information | ||||||
|
Liebert FPC 50-125kVA
|
||||||
| 50-125kVA | 208, 380, 400, 415, 480, 600 VAC | 208/120, 380/220, 400/230, 415//240 VAC | 78.5 in | 48.6 in | 39.5 in | 1335-2423 lbs |
| See more product information | ||||||
|
Liebert FPC 150-300kVA
|
||||||
| 150-300kVA | 208, 380, 400, 415, 480, 600 VAC | 208/120, 380/220, 400/230, 415//240 VAC | 78.5 in | 48.6 in | 39.5 in | 1360-3040 lbs |
| See more product information |
Benefits
Features
*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.
Frequently Asked Questions
- Q
- Can the product be customized?
- A
- There are many custom solutions available for our products. Please contact your local sales office for more information.
- Q
- Can circuits be added without powering the unit down?
- A
- OSHA defines safety procedures for energized equipment. You may also have local codes or standards to follow. Beware of competitors who state without details that it is okay to work on energized equipment.